CFFCW - 4906,4909,5921,5922,7385,7386 AMINOPHYLLINE INJECTION,USP
- MSDS: CFFCW
- Manufacturer: ABBOTT LABORATORIES DIAGNOSTICS DIV
- Product Name: 4906,4909,5921,5922,7385,7386 AMINOPHYLLINE INJECTION,USP
- National Stock Number: 6505-00-105-9500
Product Identification
Product ID:4906,4909,5921,5922,7385,7386 AMINOPHYLLINE INJECTION,USP
MSDS Date:05/18/1996
FSC:6505
NIIN:00-105-9500
MSDS Number: CFFCW
Responsible Party
NORTH CHICAGO, IL 60064-3500
US
Emergency Phone: 847-937-7970/800-424-9300(CHEMTREC)
Info Phone: 800-323-9100
Preparer: FM
Cage: 4W445
Contractor
Telephone: 800-323-9100
Cage: 4W445
Ingredients
5877-66-5)
RTECS: XH5602000
WATER
CAS: 7732-18-5
RTECS: ZC0110000
Hazards
LD50 LC50 Mixture:INGESTION RATING:POSSIBLY TOXIC.
Routes of Entry: Inhalation:NO Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:IN CLINICAL USE MATL EFFECTS LUNGS TO
AID BREATHING.ACTIVE INGRED IS TOXIC BY INGEST & PRODUCES CHANGES
IN HEART,CNS,KIDNEYS & SKELETAL MUSCLES.ANIMAL DATA SUGGEST IT CAN
PRODUCE ADVERSE EFFECTS TO TE STES & FETUS.TAR
ORGANS:LUNGS/HEART/CNS/SKELETAL MUSCLE,TESTES,REPRODUCTION,KIDNEYS.
Explanation of Carcinogenicity:PER MSDS:NONE;NTP/IARC/OSHA:NOT LISTED.
Effects of Overexposure:NOT DETERMINED.IN CLINICAL USE ADVERSE RXS
INCLUDE NAU,VOMIT W/BLOOD,GI
DISTRESS,DIARR,HEAD,IRRITABILIYT,RESTLESSNESS,INSOMNIA,PALPITATIONS
,INCR HEART RETE,FLUSING,LOWERED BLOOD PRESSURE,INCR RESP,ALB
UMINURIA,INCR URINE OUTPUT,RASHES.
Medical Cond Aggravated by Exposure:N/D.HYPERSENS TO
THEOPHYLLINE/EHTYLENEDIAMINE.CONCURRENT XANTHINE THERAPY.PRE-EXIST
SEVERE CARDIAC DISEAS,SEVERE
HYPOXIA,HYPERTENSION,HYPERTHYROIDISM,ACUTE CARD INJURY,PEPTIC
ULCER,OCNVULS,(SUPPLEMEN)
First Aid
First Aid:EYE/SKIN/INHAL/INGEST:REMOVE FROM EXPO.FLUSH EYE/SKIN
W/COPIOUS AMTS OF H2O.IRRIT PERSIST/TOXIC SIGN OCCUR GET MED
ATTN.PROVIDE SYMPT/SUPP CARE.MONITOR FLUIDS,BLOOD PRESSURE,BODY
TEMPS,RESPIRATION,CON VULSIVE ACTIVITY AS NECESSARY.
Fire Fighting
Flash Point:NON-FLAMMABLE
Autoignition Temp:Autoignition Temp Text:NP
Lower Limits:ND
Upper Limits:ND
Extinguishing Media:USE MEDIA APPROPRIATE FOR PRIMARY CAUSE OF FIRE.
Fire Fighting Procedures:WEAR PROTECTIVE CLOTHING & SELF-CONTAINED
BREATHING APPARATUS.
Unusual Fire/Explosion Hazard:NONE.
Accidental Release
Spill Release Procedures:ABSORB W/SUITABLE MATERIAL, FLUSH W/WATER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:NO SPECIAL HANDLING REQUIRED.STORE
@CONTROLLED ROOM TEMPS OF 15-30C(59-85F).PROTECT FROM LIGHT.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.
Exposure Controls
Respiratory Protection:NONE REQUIRED UNDER NORMAL PROUDCT USE
CONDITIONS.
Ventilation:NO SPECIAL PROVISIONS REQUIRED UNDER NORMAL PRODUCT USE
CONDITIONS.
Protective Gloves:IMPERVIOUS GLOVES RECOMMENDED IF CONTACT
Eye Protection:NOT REQUIRED,RECOMMENDED IF CONTACT
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
CONDITIONS AGGRAV:ARRYHYTHMIAS,CONGESTIVE HEART FAILURE,LIVER
INJURY.GI/URINARY AILMENTS.CONCURRENT USE OF EPHEDRINE,LIGHTIUM
CARBONATE,PROPANOLOL,CIMETIDINE,ERYTHROMYCIN & TROLEANDOMYCIN.
Chemical Properties
HCC:N1
Boiling Pt:B.P. Text:WATER
Melt/Freeze Pt:M.P/F.P Text:WATER
Decomp Temp:Decomp Text:NP
Vapor Pres:NA
Vapor Density:NA
Spec Gravity:WATER
pH:8.5-9
Viscosity:NP
Evaporation Rate & Reference:NA
Solubility in Water:AQUEOUS SOLUTION
Appearance and Odor:CLEAR LIQUID, ODOR:NA
Percent Volatiles by Volume:NP
Corrosion Rate:NP
Stability
Stability Indicator/Materials to Avoid:YES
NOT DETERMINED
Stability Condition to Avoid:PROTECT FROM LIGHT AND HEAT.
Hazardous Decomposition Products:WHEN HEATED TO DECOMPOSITION IT EMITS
TOXIC FUMES OF NOX.
Disposal
Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH LOCAL, STATE AND
FEDERAL REGULATIONS.CERCLA/RCRA/SARA:NOT LISTED.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.